If you do not remove all power, the system will not recognise the module. Page Wiring The Control Unit 3. It is designed to stand away from the wall to leave space for the cables. Mains Connection Connect the control unit to a suitable supply using a double pole disconnect device in accordance with EN Clause 3. Page Keypads 3. Installation Keypads Connecting Keypads Figure 10 shows the connections for keypads.

Use the "ET" connector terminals on the keypad PCB to connect an exit terminate button or lock switch. If you are using a lock switch, do not connect any other devices to these terminals. Page Connecting Sounders 3.

Installation Keypad Addressing The control unit is supplied with one keypad. If you have fitted more keypads, each one must be given a separate "address". Keypad 1 Keypad 2 Address Page 23 3. The table below summarises the number and type of zones that can connect to the main PCB of the control unit. Use Command 21 to specify which of these wiring types you are using. Page Figure Fsl Connections 3. Installation The wiring resistance of the cable to the detector including joints should not exceed ohms.

The recommended maximum cable length within a zone is —m. Page Programming Outputs 3. Installation Programming Outputs Control unit panel outputs can be programmed using the commands shown in the table below. Open collector outputs are of a "pull down" type that provides negative-applied control signals; the system adjusts the output polarity when you select the output type. Page Wiring Keyswitches 3. Installation Wiring Keyswitches To allow a user to set and unset the system using a keyswitch, connect a fixed position or spring loaded momentary key switch to a zone input.

Note that a key switch cannot reset the system. When programming the control unit select zone type KM for momentary or KF for fixed position keyswitches. Page 28 3. Installation The can be connected to either a momentary or a latched keyswitch see Figure Note: If you connect a keyswitch through a keyswitch interface, it can be used to set and unset the whole system or Level B only.

Page Communicator 3. Installation Communicator The can be fitted with a communicator or speech dialler, for example the Scantronic , , and digital communicators or the SD1 or SD2 Speech diallers. To connect an SD1 or SD2 follow the instructions provided with those products. Fitting A Plug-By Communicator 3. Installation Figure Fitting a Plug-by Communicator Make any necessary connections from the communicator to the communication wiring harness.

The default is a positive voltage when the output is inactive but this can be inverted if required using Command Page Fitting A Battery 3. Installation If the system has already been installed: Re-connect the battery. Fit the case lid. Apply mains power. Test communicator operation. Fitting a Battery Fit a rechargeable battery into the back of the case.

There is space in the case for a 12V 7Ah battery; Page Programming 4. Introduction provides an overview of how to program a control unit. Programming Commands lists and describes the commands available to program aspects of a control unit's operation.

Page Entering Installer Mode Programming 2. Duress mode provides the same access as user mode but also secretly communicates the duress status.

There is only one user code of this type. Entering Installer Mode Chapter 3 describes how to enter installer mode for the first time in a new installation. The system is now in user mode. Note: If any hour, Fire, PA or Technical zones are active when you enter Command 99, the keypad gives an error tone and displays the faults.

Correct the problems identified. To purchase tags from Cooper Security, quote part number Proxtagpk5. A tag acts as an alternative to a user access code.

You can assign a user a tag, an access code, or both. The display shows: Select? Press 4 to select the change codes option. Use Command to select language without making other changes. Note: If you select options 6 or 7 Finland, Norway, Sweden or If a Technical Alarm zone is activated while the system is set, the system makes no audible alarm.

Use this type for zones connected to standalone external keypads or access controllers. If the zone is triggered by the external keypad during the exit time, the control unit stops the exit time and sets the system. Armed in When applied, the zone is armed when the Level C After an alarm, the user keys in an access code to silence the alarm but cannot reset the system. The first alarm message to display and the Service lamp remain visible.

System operates the internal sounders only. System operates both internal and external sounders. If you select option 0 the default , the system gives an immediate alarm when the user strays from an Entry Route zone during entry.

To permit a user reset, select option 0 the default. Page 48 Programming - Programming Commands Daytime Tamper Communication This command defines how the control unit reports tamper indications for example, an attempt to open a control unit or keypad case while the alarm system is unset. Option Internal sounder only default.

The keypads give a double "beep" confirmation tone at the end of all setting modes, including Silent Set. The default is option 0, Timed. Option Timed. Page 50 Programming - Programming Commands If an intruder opens the Final Exit door without first unlocking the lock switch, the control unit immediately starts an unconfirmed alarm.

If the intruder goes on to violate another zone and Alarm Confirmation is enabled, the control unit sends a confirmed alarm. Page 51 Programming - Programming Commands Bell Duration When an alarm occurs for example, an intruder violates a zone , the system waits for the Bell Delay before operating the external sounder for the Bell Duration.

This command sets the Bell Duration. Page 52 Programming - Programming Commands Tamper Alarm Response his command specifies which sounders the control unit will activate for a Tamper Alarm while the system is unset.

Option Internal sounders only default Keypad sounders only Internal and keypad sounders Lockout Keypads During Entry This command enables you to lock keypads during entry when proximity tag readers or remote setting devices are being used to unset the system.

Option Use the reset option selected for the system with Command 33 default. Permit the user to reset after an abort. If you select option 1, these zones act as Normal Alarm zones during part set B. Option Keypad sounders only. Internal sounders and keypad sounders default.

Local alarm internal and external sounder only. Page 57 Programming - Programming Commands Forbikobler Door Locking This command specifies whether the door controlled by the Forbikobler system is normally unlocked while the system is reset or opened only for a controlled time.

Even if the door is normally unlocked, it can be locked with a user command if required. Page 58 Programming - Programming Commands Local alarm internal and external sounder only. Option 10 seconds 20 seconds default 30 seconds 45 seconds 60 seconds seconds For this reason, Cooper Security recommends that you use Level D for simple applications only. Page 60 Programming - Programming Commands Armed Lamp: active continuously while the system is full or part set. Set Latch: active when the system is set and inactive when the system is unset or an alarm condition occurs.

It is active for one second when a reset is performed or the control unit leaves installer mode. Pulse Set 4: active for time set by Command Pulse Unset 1: active for time set by Command Pulse Unset 2: active for time set by Command Pulse Unset 3: active for time set by Command Notes: Selecting option 1 also enables any PAs connected to keyswitch interfaces or to keypads. Your alarm system is fitted with a liquid crystal display LCD keypad. Join Co-production practitioners network.